Floor Slab Insulation Detail

Diagram Of Structural Concrete Slab Floor With Underfloor Heating Pipes Floor Insulation Heated Concrete Floor Floor Heating Systems

Diagram Of Structural Concrete Slab Floor With Underfloor Heating Pipes Floor Insulation Heated Concrete Floor Floor Heating Systems

Http Basc Pnnl Gov Sites Default Files Images Te 204 2 20slab 20independent 20of 20foundation 20wall 20 Jpg Concrete Footings Concrete Pad Rigid Insulation

Http Basc Pnnl Gov Sites Default Files Images Te 204 2 20slab 20independent 20of 20foundation 20wall 20 Jpg Concrete Footings Concrete Pad Rigid Insulation

Trench Fill Foundation Detail Google Search Building Foundation Architecture Foundation Concrete Slab

Trench Fill Foundation Detail Google Search Building Foundation Architecture Foundation Concrete Slab

Insulating Concrete Slabs For Radiant Floor Heating Systems Floor Heating Systems Radiant Floor Heating Hydronic Radiant Floor Heating

Insulating Concrete Slabs For Radiant Floor Heating Systems Floor Heating Systems Radiant Floor Heating Hydronic Radiant Floor Heating

Slab On Grade Foundation Details Building Foundation Foundation Pier And Beam Foundation

Slab On Grade Foundation Details Building Foundation Foundation Pier And Beam Foundation

Insulated Concrete Grade Beam Floor Slab And Wall Detail Slab Foundation Building Foundation House Foundation

Insulated Concrete Grade Beam Floor Slab And Wall Detail Slab Foundation Building Foundation House Foundation

Insulated Concrete Grade Beam Floor Slab And Wall Detail Slab Foundation Building Foundation House Foundation

These codes do not require any insulation for slabs that are more than 12 in.

Floor slab insulation detail.

If headroom is tight then the only option may be to break up the existing slab dig further down and build up an entirely new floor. Rigid insulation is placed horizontally under the slab perimeter and vertically in the joint at the slab edge. In new hampshire chris roche is pulling together plans for a new energy efficient home. Slabs lose energy primarily as a result of heat conducted outward and through the perimeter of the slab.

This technique can limit inward vapor movement when the sun shines on damp bricks. Remember that your slab will be about 75 degrees f. Illustration by chris roche. The codes are silent about whether above grade slabs need to be insulated.

Continuous insulation is applied directly to the underside of the slab and extends inward horizontally from the perimeter for the distance specified or continuous insulation is applied downward from the top of the slab and then extends horizontally to the interior or the exterior from the perimeter for the distance specified. In this insulation detail at the perimeter of the slab a total of 6 inches of rigid foam insulation separates the interior slab from the outdoors. Such spaces typically have a sound level concrete slab floor but lack sufficient floor insulation to achieve the thermal performance targets for new habitable rooms. Mainly heated slabs radiate outward rather than downward so insulation on the edges of the slab is most important.

4 10 2012 3 climate zones e301 1 6 5 8 4 slab r value table 402 1 1 insulation and fenestration requirements by component e402 1 1 climatezone slab r valued 4 10 2 ft 5 10 2 ft 6 10 4 ft 9. If the insulation is going below the slab the damp proof membrane dpm is laid next followed by the insulation a polythene separating layer and the concrete slab. Otherwise both codes require that slab on grade floors with a floor surface less than 12 in. Any cooler surface in contact with the slab will try to steal its heat.

Depending on the use of the building the slab can then be finished ready for use or receive a screed suitable for a floor finish. Installing slab insulation around the perimeter of the slab will reduce heat loss and make the slab easier to heat. Additionally a layer of rigid foam is used between the framing and ventilation space behind the brick cladding.

Heat Loss Through Footings Building Foundation Slab Insulation Slab Foundation

Heat Loss Through Footings Building Foundation Slab Insulation Slab Foundation

Floor Insulation Concrete Floor On Floor Eifs Exterior Insulation And Finishing System Details 2 Concrete Floor Insulation Concrete Floors Exterior Insulation

Floor Insulation Concrete Floor On Floor Eifs Exterior Insulation And Finishing System Details 2 Concrete Floor Insulation Concrete Floors Exterior Insulation

Insulated Slab On Grade With Wall Detail Note Extension Of Insulation Board Beyond Edge Of Footer Concrete Design Slab Foundation Concrete Floors

Insulated Slab On Grade With Wall Detail Note Extension Of Insulation Board Beyond Edge Of Footer Concrete Design Slab Foundation Concrete Floors

Code Regarding Slab Insulation 12 Slab Needs R10 Or R15 With Hydro Heat Insulation Rigid Insulation Slab

Code Regarding Slab Insulation 12 Slab Needs R10 Or R15 With Hydro Heat Insulation Rigid Insulation Slab

Source : pinterest.com