Ceiling fire dampers also known as radiation dampers are designed and tested to limit the radiant heat transfer through an air inlet outlet opening in the ceiling membrane of a fire resistance rated floor ceiling or roof ceiling assembly.

Floor radiation dampers.

Ceiling fire damper may be installed in floor ceiling and roof ceiling assemblies with fire ratings of 3 hours and less. Series 51sb in a boot true truss. Application ul fire rated floor ceiling assemblies. A ceiling radiation damper shall be provided where the ceiling membrane of a fire resistance rated floor ceiling or roof ceiling assembly a listed smoke damper designed to resist the passage of smoke shall be provided at each point a duct or air transfer opening penetrates a corridor.

Ceiling radiation dampers. Operated by a fuse link these dampers come spring loaded and are available with an easy access assembly. A ceiling radiation damper shall be provided where the ceiling membrane of a fire resistance rated floor ceiling or roof ceiling assembly constructed as permitted in section 708 4 exception 2 of the international building code is penetrated. Nailor model 0722 ceiling dampers are for use in round applications in lieu of hinged door type dampers in any ul ulc floor ceiling or roof ceiling assembly with up to a 3 hour fire resistance rating where air ducts are allowed.

A ceiling radiation damper closes automatically to restrict the passage of heat. Preventing the transfer of heat and flames into attic and crawlspaces is essential in limiting the amount of damage done in the. Static ceiling radiation dampers models mrcd mscd mscdsb mccd ceiling radiation dampers covered under ul 555c intended for installation in hourly rated fire resistive floor ceiling and roof ceiling assemblies in accordance with the standard for fire tests of building construction and materials ul 263. Unlike spring loaded fire dampers and smoke dampers ceiling radiation dampers from lloyd industries limit the transfer of heat into attics or through openings in the ceilings and floors.

Ceiling radiation dampers are intended to limit the transfer of radiant heat into the concealed space when installed in the ceiling membrane of a fire resistance rated floor ceiling or roof ceiling assembly. They are used to protect hvac openings in fire rated horizontal ceiling assemblies. Now with this true round radiation dampers architectural round diffuser with volume control may be used in place of square or rectangle flush mount diffuses. Ceiling radiation dampers are available in butterfly style and curtain style.

Exteneded collar models 0722 se and 0722 le available.

8 X 8 In Galvanized Steel Manual Butterfly Ceiling Radiation Damper With 7 In Sleeve 3 Set Back Winsupply

8 X 8 In Galvanized Steel Manual Butterfly Ceiling Radiation Damper With 7 In Sleeve 3 Set Back Winsupply

Pottorff Mobile

Pottorff Mobile

Ceiling Radiation Dampers

Ceiling Radiation Dampers

2700cba 1 Hour Rated Ceiling Radiation Damper With Register Box Assembly

2700cba 1 Hour Rated Ceiling Radiation Damper With Register Box Assembly

Source : pinterest.com